Test Report

Testing Scope

The scope of testing revolved around verifying the compliance of the product as per the specifications published by MOSIP using the below devices: Registration devices for iris, face and fingerprint Authentication devices for the iris, face and fingerprint The compliance tool kit was tested with the below biometric specifications:

  1. SBI a. Registration b. Authentication

  2. SDK a. Quality Check b. 1: N Match c. Extraction d. Conversion

Test Execution Statistics

SBI Testing

The Secure Biometric Interface (SBI) is used to interface with biometric devices. The compliance tool kit was tested to ensure that the interface built by the device provider follows the specs and security rules defined in the SBI spec.

For Authentication Devices using MOSIP's mock SBI devices

The MOSIP’s Mock SBI has been tested for compliance with the specifications across 48 test cases. Test cases specific to quality and user interactions have been tested with real devices rather than mock.

Scenarios

Finger

Iris

Face

Total

17

18

13

Passed

17

18

13

Pending

0

0

0

Failed

0

0

0

Test Rate (%)

100%

100%

100%

Pass Rate (%)

100%

100%

100%

For Registration Devices using MOSIP's mock SBI devices

The MOSIP’s Mock SBI has been tested for compliance with the specifications across 65 test cases. Test cases specific to quality and user interactions have been tested with real devices rather than mock.

Scenarios

Finger

Iris

Face

Total

30

18

17

Passed

30

18

17

Pending

0

0

0

Failed

0

0

0

Test Rate (%)

100%

100%

100%

Pass Rate (%)

100%

100%

100%

For Authentication Devices using MOSIP's real devices (only finger)

The MOSIP’s real devices have been tested for compliance with the specification only for fingerprint and iris devices.

Scenarios

Finger

Iris

Face

Total

17

18

13

Passed

14

1

0

Pending

0

0

13

Failed

3

17

0

Test Rate (%)

100%

100%

0%

Pass Rate (%)

82%

6%

0%

For Registration Devices using MOSIP's real devices

The MOSIP’s real SBI has been tested for compliance with the specifications for iris, face and fingerprint devices.

Scenarios

Finger

Iris

Face

Total

30

18

17

Passed

30

18

17

Pending

0

0

0

Failed

0

0

0

Test Rate (%)

100%

100%

100%

Pass Rate (%)

100%

100%

100%

SDK Testing

The SDK implementation has been tested to support quality checks, 1:N matches, extraction, and conversion of biometrics.

Out of scope: Segmentation testing

Scenarios.

With Mock SDK

With Real SDK 1

With Real SDK 2

Total

76

76

76

Passed

66

27

51

Pending

0

0

0

Failed

1

11

16

Not Applicable

9

28

9

Test Rate (%)

88%

50%

88%

Pass Rate (%)

87%

36%

67%